When moving house, renovating a room, or changing the installation location of a Hitachi split air conditioner, many users want to reuse the existing copper pipes to save costs. However, not all pipes are suitable for reuse. When can existing copper pipes be retained, and when should they be replaced to ensure reliable air conditioner operation? Let's find out with U.P Tech.

Hitachi split air conditioner and copper refrigerant pipes.
What to consider when reusing existing copper pipes to relocate a Hitachi split air conditioner.

Is It Necessary to Replace Copper Pipes When Relocating a Hitachi Air Conditioner?

When relocating a Hitachi Wall Mounted Air Conditioner, you do not necessarily need to replace all the copper pipes. If the existing piping is still in good condition and suitable for the new installation location, it can be reused to reduce costs.

Before reinstallation, however, a qualified technician should check whether the pipes have been damaged during removal and whether they still meet the unit's technical requirements.

4 Conditions for Reusing Old Copper Pipes When Relocating a Hitachi Air Conditioner

To determine whether existing copper pipes can be reused, the following four conditions should be checked:

Copper pipes are intact and free from deformation

Copper pipes may become dented, kinked, or cracked during the removal and transportation of a Hitachi air conditioner. Dents and kinks can restrict refrigerant flow, while cracks and corroded areas may cause refrigerant leakage.

Therefore, copper pipes should only be reused if they are intact, free from deformation, and show no signs of damage that could compromise their durability or pressure resistance.

Pipe specifications are compatible with the equipment

The diameter, wall thickness, and pressure resistance of copper pipes must meet the requirements of each Hitachi split air conditioner model.

If the same unit is being relocated, the existing piping may be reused if it remains in good condition and was originally installed according to the required specifications. When installing a new unit, compatibility with the refrigerant type and technical specifications must also be checked against the manufacturer's instructions.

Pipe length is suitable for the new installation location

When relocating a Hitachi air conditioner, the distance between the indoor and outdoor units may change. The pipe length and height difference between the two units must remain within the manufacturer's specified limits.

If the existing copper pipes are too short, they should not be forcibly stretched or bent to fit the new installation location, as this may damage the piping.

The piping is clean and leak-tight

Copper refrigerant pipes should only be reused when their interiors are clean, dry, and free from contaminants that could affect system operation.

A technician should inspect the pipe connections, address any defects, and perform leak testing to detect and resolve leaks before commissioning the system.

Hitachi airHome 100 wall-mounted air conditioner
>>> Learn more about the Hitachi airHome 100 wall-mounted air conditioner.

How to Handle Existing Copper Pipes When Relocating a Hitachi Air Conditioner

Can existing copper pipes be extended if they are too short?

If the new installation location of a Hitachi air conditioner requires longer piping, a technician may extend the existing pipes if permitted by the manufacturer.

However, if multiple joints are required or the connection points are difficult to inspect, replacing the piping should be considered to reduce the risk of refrigerant leakage.

Do copper pipes need to be replaced if the insulation or flared ends are damaged?

Damaged or deteriorated pipe insulation does not necessarily mean that the entire copper piping system needs to be replaced. If the copper pipes are still in good condition, only the insulation needs to be replaced.

For damaged flared ends, a technician may remove the affected sections and remake the flares, provided sufficient pipe length remains for proper connection.

When should all copper pipes be replaced?

Complete replacement is recommended when the piping has deteriorated in multiple areas, does not meet the required technical specifications, or contains contaminants that cannot be adequately removed.

If the cost of repairing and extending the existing piping is too high, installing new copper pipes may also be a more cost-effective option, helping reduce potential repair costs after installation.

Hitachi PJ CMV Series Inverter Wall-Mounted Air Conditioner
>>> Learn more about the Hitachi PJ CMV Series Inverter Wall-Mounted Air Conditioner.

Important Considerations When Reusing Copper Pipes for Hitachi Air Conditioner Installation

Proper removal and protection of refrigerant piping

Before removing a Hitachi split air conditioner, a qualified technician must follow the manufacturer's instructions for refrigerant recovery or pump-down, as applicable.

During removal and transportation, repeated bending of copper pipes should be avoided, and both pipe ends should be sealed to prevent dust and moisture from entering.

Leak testing and vacuum evacuation

After connecting the indoor and outdoor units, the technician must perform leak testing, vacuum evacuation, and refrigerant leakage checks according to the instructions for the specific model.

These procedures are essential whether new or existing copper pipes are used.

Refrigerant checks and test operation

Relocating an air conditioner does not necessarily mean that additional refrigerant is required. The technician should determine whether additional refrigerant is needed based on the system condition, pipe length, and manufacturer's instructions.

Once installation is complete, the unit should be tested to check cooling performance, noise, vibration, and condensate drainage.

Contact U.P Tech for Hitachi Split Air Conditioner Consultation

Reusing existing copper pipes when relocating an air conditioner can help reduce costs. However, a qualified technician should inspect the piping before deciding whether to retain or replace it to ensure reliable operation.

As a distributor of Hitachi air conditioning products, U.P Tech offers cooling solutions for residential and commercial spaces. Contact U.P Tech via our hotline at 1800 6202 to learn more about Hitachi Wall Mounted Air Conditioner and receive advice on suitable installation solutions for your space.


You may also be interested in:

>>> Can Dry mode on a Hitachi air conditioner replace a dehumidifier?

>>> Should you stock Hitachi chiller spare parts to reduce downtime?

>>> Can Two Hitachi VRF Circuit Boards That Look Alike Be Used Interchangeably?


U.P. TECHNOLOGY AND TRADING CO., LTD.

Hotline: 1800 6202

Email: vu@uptech.com.vn

Website: https://uptech.com.vn

Head Office: D6, Thuan Viet Commercial Area, 319 Ly Thuong Kiet Street, Phu Tho Ward, Ho Chi Minh City, Vietnam.

Ho Chi Minh City Transaction Office: 370 Cach Mang Thang 8 Street, Nhieu Loc Ward, Ho Chi Minh City, Vietnam.

Hanoi Transaction Office: 14th Floor, ADI Building, Lot HH03, To Huu Street, Ha Dong Ward, Hanoi, Vietnam.
 

Ceiper
Zalo